Table 21.13 Status Code

Code
Description
H'11
Device Selection Wait
H'12
Clock Mode Selection Wait
H'13
Bit Rate Selection Wait
H'1F
Programming/Erasing State Transition Wait (Bit rate selection is completed)
H'31
Programming/Erasing State
H'3F
Programming/Erasing Selection Wait (Erasure is completed)
H'4F
Program Data Receive Wait (Programming is completed)
H'5F
Erase Block Specification Wait (Erasure is completed)

Table 21.14 Error Code

Code
Description
H'00
No Error
H'11
Checksum Error
H'12
Program Size Error
H'21
Device Code Mismatch Error
H'22
Clock Mode Mismatch Error
H'24
Bit Rate Selection Error
H'25
Input Frequency Error
H'26
Division Ratio Error
H'27
Operating Frequency Error
H'29
Block Number Error
H'2A
Address Error
H'2B
Data Length Error
H'51
Erasing Error
H'52
Erasure Incomplete Error
H'53
Programming Error
H'54
Selection Processing Error
H'80
Command Error
H'FF
Bit-Rate-Adjustment Confirmation Error
Section 21 Flash Memory (0.18-µm F-ZTAT Version)