Section 7 Data Transfer Controller (DTC)
7.5.1

Normal Mode

In normal mode, one activation source transfers one byte or one word of data. Table 7.3 lists the
register functions in normal mode. From 1 to 65,536 transfers can be specified. Once the specified
number of transfers has been completed, a CPU interrupt can be requested.
Table 7.3
Register Functions in Normal Mode
Name
DTC source address register
DTC destination address register
DTC transfer count register A
DTC transfer count register B
SAR
Rev. 3.00 Jul. 14, 2005 Page 148 of 986
REJ09B0098-0300
Abbreviation
SAR
DAR
CRA
CRB

Figure 7.5 Memory Mapping in Normal Mode

Function
Transfer source address
Transfer destination address
Transfer counter
Not used
Transfer
DAR