Interrupt Control Modes And Interrupt Operation; Table 5.6 Interrupt Control Modes - Renesas H8S Series Hardware Manual

16-bit single-chip microcomputer
Hide thumbs Also See for H8S Series:
Table of Contents

Advertisement

5.6

Interrupt Control Modes and Interrupt Operation

The interrupt controller has two modes: interrupt control mode 0 and interrupt control mode 1.
Interrupt operations differ depending on the interrupt control mode. NMI and address break
interrupts are always accepted except for in the reset state or in hardware standby mode. The
interrupt control mode is selected by SYSCR. Table 5.6 shows the interrupt control modes.
Table 5.6
Interrupt Control Modes
Interrupt
SYSCR
Control
Mode
INTM1
0
0
1
0
Priority
Setting
INTM0
Registers
0
ICR
1
ICR
Interrupt
Mask Bits
Description
I
Interrupt mask control is performed by
the I bit. Priority levels can be set with
ICR.
I, UI
3-level interrupt mask control is
performed by the I and UI bits. Priority
levels can be set with ICR.
Rev. 3.00 Jul. 14, 2005 Page 109 of 986
Section 5 Interrupt Controller
REJ09B0098-0300

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8s/2100 seriesH8s/2114rR4f2114r

Table of Contents