Command Reference Guide
connect-sequence interface-recovery
Use the connect-sequence interface-recovery command to allow the interface to go down in the event
that the connect-sequence attempts value is exhausted. Refer to
page 2097
for more information. Use the no form of this command to restore the default value. Variations
of this command include:
connect-sequence interface-recovery
connect-sequence interface-recovery retry-interval <value>
connect-sequence interface-recovery retry-interval <value> max-retries <number>
Syntax Description
retry-interval <value>
max-retries <number>
Default Values
By default, the connect-sequence interface-recovery retry-interval is set to 120 seconds and
max-retries are unlimited.
Command History
Release 11.1
Usage Examples
The following example configures demand interface 1 to wait 60 seconds between retry attempts with a
maximum number of 500 retries:
(config)#interface demand 1
(config-demand 1)#connect-sequence interface-recovery retry-interval 60 max-retries 500
60000CRG0-35E
Optional. Specifies the number of seconds the interface will wait between
connect sequence cycles during recovery attempts.
Optional. Specifies the maximum number of times the connect sequence
will cycle in an attempt to bring the interface back up. When in interface
recovery mode, this value overrides the connect-sequence attempts
value.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.
Demand Interface Command Set
connect-sequence attempts <value> on