ABB IRB 6700Inv Series Product Manual page 89

Hide thumbs Also See for IRB 6700Inv Series:
Table of Contents

Advertisement

3
4
5
6
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
Action
The bracket on the delivered fan cable must be
fitted at a distance of 1,150 mm from the base
connector.
If adjustment is needed: measure the distance
and make a mark with a pen or a piece of self
adhesive. Loosen the cable bracket nuts and
move the bracket to the mark. Tighten the nuts
with 10 Nm after adjustment.
Loosen the frame cable clamp by unscrewing the
screws.
Run the cabling up through the base and frame.
Make a loop of the fan cable and use cable straps
to strap it to the other cables.
Secure the cable bracket inside the frame with
the two enclosed nuts.
© Copyright 2017 - 2020 ABB. All rights reserved.
2 Installation and commissioning
2.7.2 Installing the motor cooling fan (option)
Note
1150
xx1800000163
xx1300000542
Cable straps
xx1800000164
xx1800000166
Continues on next page