Refitting the cable harness - lower arm
1
2
3
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
Action
Tip
Use tape and tie the axis-5 and axis-6
connectors and carrier into a bundle (if not
already done). This is done to facilitate the
procedure and to avoid damaging the parts
during the procedure.
This will also make it easier to run the cable
harness through the inside of the robot.
Run the upper end of the cable harness up
through the lower arm.
Refit the axis-2 lower arm metal clamp
located on the inside of the lower arm.
Note
The screws are reached from the outside
of the lower arm.
© Copyright 2017 - 2020 ABB. All rights reserved.
4.5.5 Replacing the lower arm
Note
xx1300000668
xx1300000733
xx1300000734
Continues on next page
4 Repair
Continued
371