4 Repair
4.7.5 Replacing the axis-5 motor
Continued
2
3
4
5
Continues on next page
516
Action
Refit the cable gland cover by performing
the following steps:
Slide the cable gland cover onto the
inner screw.
Refit and tighten the outer screw.
Tighten the inner screw. Make sure
that the gasket is not damaged.
Note
Replace the gasket if damaged.
Connect the connectors.
Connect in accordance with the markings
on the connectors.
Make sure the o-ring on the motor is undam-
aged.
Replace if damaged.
CAUTION
When fitting the motor cover, make sure
that none of the cables inside will be dam-
aged.
© Copyright 2017 - 2020 ABB. All rights reserved.
Note
xx1200001016
xx1200001015
O-ring, axis 5: 3HAC054692-001.
xx1200001021