4 Repair
4.7.2 Replacing the axis-2 motor
Continued
5
6
Securing the axis-2 motor
1
2
3
Continues on next page
474
Action
If the motor is a new spare part, remove the cover.
Foundry Plus:
Valid for axis-2, axis-3, axis-4 and axis-6 motors.
If the motor is a new spare part, the evacuation
hole protection filter must be replaced with a
transparent plug/sight glass (enclosed with the
spare part delivery). Remove the protection filter
and install the transparent plug/sight glass.
On the axis-6 motor there are two protection filters
that must be replaced with transparent plugs/sight
glasses.
xx1800000101
Protection filter (Stand-
ard).
Action
Fit guide pins in opposite holes.
CAUTION
The motor weighs 28 kg.
All lifting accessories used must be sized
accordingly.
Apply the lifting accessory.
© Copyright 2017 - 2020 ABB. All rights reserved.
Note
xx1200001135
Tightening torque, transparent
plug: 25 Nm ±10%.
Tightening torque, protection filter:
10 Nm ±10%.
xx1600000576
xx1800000102
Transparent plug
(Foundry Plus).
Note
Guide pin, M10x150: 3HAC15521-2
Always use guide pins in pairs.
Lifting accessory, motor: 3HAC15534-1
Lifting accessory (chain): 3HAC15556-1