Removing the axis-1 motor
These procedures describe how to remove the motor.
Preparations before removing the axis-1 motor
1
2
3
Disconnecting the motor cables
1
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
Action
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Action
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
Jog the robot to the synchronization posi-
tion.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safe-
guarded space.
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
© Copyright 2017 - 2020 ABB. All rights reserved.
4.7.1 Replacing the axis-1 motor
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
Reference calibration
routine on page
684.
Note
Note
Continues on next page