6
Attaching the removal tool
1
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
Action
Foundry Plus:
Valid for axis-2, axis-3, axis-4 and axis-6 motors.
If the motor is a new spare part, the evacuation
hole protection filter must be replaced with a
transparent plug/sight glass (enclosed with the
spare part delivery). Remove the protection filter
and install the transparent plug/sight glass.
On the axis-6 motor there are two protection filters
that must be replaced with transparent plugs/sight
glasses.
xx1800000101
xx1800000102
Protection filter (Stand-
Transparent plug
ard).
(Foundry Plus).
Action
Foundry plus:
Remove the plastic plugs.
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.7.1 Replacing the axis-1 motor
Continued
Note
Tightening torque, transparent
plug: 25 Nm ±10%.
Tightening torque, protection filter:
10 Nm ±10%.
xx1600000576
Note
xx1700000364
Continues on next page