4 Repair
4.4.2 Refitting the cable harness
Continued
Refitting the cable harness - upper arm and wrist
These procedures describes how to refit the cable harness in upper arm and wrist.
Refitting the cable harness - upper arm
1
2
3
4
Continues on next page
248
Action
Refit the metal clamp on top of the arm
house.
Refit the arm house metal clamp.
Arrange the cables between the cable
clamps in the upper arm.
Tip
Use tape and tie the axis-5 and axis-6
connectors and carrier into a bundle (if not
already done). This is done to facilitate the
procedure and to avoid damaging the parts
during the procedure.
This will also make it easier to run the cable
harness through the inside of the robot.
© Copyright 2017 - 2020 ABB. All rights reserved.