4 Repair
4.8.3 Replacing the axis-2 gearbox
Continued
5
6
Removing the axis-2 motor
1
2
3
Continues on next page
620
Action
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
Use caution and pull out the motor cables.
Action
Before removing the motor, make sure that
the axis-2 gearbox is completely drained.
To release the brake, connect the 24 VDC
power supply.
Connect to connector R2.MP2, axis-2 mo-
tor:
+ = pin 2
- = pin 5
Remove the attachment screws.
Use a bits extender in order to reach the
screws.