3 Maintenance
3.3.2 Inspecting the oil level in axis-1 gearbox
Continued
5
6
7
Continues on next page
102
Action
Remove the protective cap.
Make sure that the valve is closed (horizont-
al) and mount the Oil level gauge
Open the valve slowly to avoid air bubbles
in the oil.
Check the oil level using the Oil level
gauge.
Required oil level is: Between level meas-
urement marks on tool
© Copyright 2017 - 2020 ABB. All rights reserved.
Note
xx1600002042
xx1600002097
If the Fork lift accessory set is assembled,
fasten the extender screw in the fork lift
pocket.
xx1700000314
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L