3.7

Commissioning of the "Table positioning" technology application

Note!
Take all the necessary safety precautions before you carry out the following
commissioning steps and switch the device on!
Safety instructions with regard to commissioning
System constellation
8400 HighLine
U V W
M
3~
A
i
X5/RFR
Controller enable
X5/DI1
Position encoder connection, track A
X5/DI2
Position encoder connection, track B
X5/DI3
Hardware limit switch connection in positive direction
X5/DI4
Hardware limit switch connection in negative direction
X5/DI5/DI6 Profile selection and change of operating mode at the same time:
0 | 0 = Profile selection 0 and request for "Speed follower" operating mode
0 | 1 = Profile selection 1 and request for "Homing" operating mode
1 | 0 = Profile selection 2 and request for "Manual jog" operating mode
1 | 1 = Profile selection 3 and request for "Positioning" operating mode
X5/DI7
Start of profile generation
X6
Diagnostic interface for connecting the USB diagnostic adapter
[3-2]
Block diagram for wiring the commissioning example for the "Table positioning" application
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Commissioning of the "Table positioning" technology application
X3
AR A1U GA
24I RFR DI1 DI2
DI5/DI6: PosProfile 0 ... 3
DI7: PosExecute
B
-30
-20
-10
0-Position
L
8400 HighLine C | Reference manual
( 54)
X5
DI3 DI4 DI5 DI6 DI7
10
20
30
40
Commissioning
DIAG
X6
X61
X6
67