C00826
Parameter | Name:
C00826 | L_DigitalLogic5_2: Function
FB L_DigitalLogic5_2: Selection of the interna logic operation
Selection list
(Lenze setting printed in bold)
Read access
C00827
Parameter | Name:
C00827 | L_DigitalLogic5_2: Truth table
FB L_DigitalLogic5_2: Parameter setting of the truth table
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 bOut = 0
1 bOut = 1
2 bOut = f (truth table)
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Info
The truth table parameterised in
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00826
Data type: UNSIGNED_8
Index: 23749
= 5CC5
d
h
C00827
is used.
Data type: UNSIGNED_8
Index: 23748
= 5CC4
d
h
857