Parameter | Name:
C00008 | Original application|control source
3012 SwitchPos|Terminal 2
3014 SwitchPos|Terminal 11
3016 SwitchPos|Terminal 16
3020 SwitchPos|Keypad
3021 SwitchPos|PC
3030 SwitchPos|CAN
3040 SwitchPos|MCI
Read access
C00010
Parameter | Name:
C00010 | AIN1: Characteristic
From version 04.00.00
Setting range
(min. value | unit | max. value)
0.00
Subcodes
C00010/1
C00010/2
C00010/3
C00010/4
C00010/5
C00010/6
C00010/7
C00010/8
Read access
C00011
Parameter | Name:
C00011 | Appl.: Reference speed
Setting the reference speed
• In the controller, all speed-related signals are processed to one reference variable in percent.
• Set a reference speed here that corresponds to 100 %.
• The frequency that corresponds to the set reference speed is displayed in C00059.
Note:
This is not a maximum limitation!
All values in percent in the controller may be in a range of 0 ... 199.99 %.
Setting range
(min. value | unit | max. value)
50
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Write access
CINH
PLC STOP
%
Lenze setting
0.00 %
0.00 %
0.00 %
0.00 %
100.00 %
100.00 %
100.00 %
100.00 %
Write access
CINH
PLC STOP
rpm
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Application: Switch-off positioning
I/O level: "Terminal 2" control mode
Application: Switch-off positioning
I/O level: "Terminal 11" control mode
Application: Switch-off positioning
I/O level: "Terminal 16" control mode
Application: Switch-off positioning
I/O level: "Keypad" control mode
Application: Switch-off positioning
I/O level: "PC" control mode
Application: Switch-off positioning
I/O level: "CAN" control mode
Application: Switch-off positioning
I/O level: "MCI" control mode
No transfer
COM
MOT
Scaling factor: 1
Analog
terminals:
199.99
Info
AIN1: (+y0) = min
AIN1: (+x0) = Dead band
AIN1: (-y0) = (-min)
AIN1: (-x0) = (-Dead band)
AIN1: (+ymax)
AIN1: (+xmax)
AIN1: (-ymax)
AIN1: (-xmax)
No transfer
COM
MOT
Scaling factor: 100
Lenze setting
60000 1500 rpm
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00010
Data type: UNSIGNED_16
Index: 24567
= 5FF7
d
Data type: INTEGER_16
Index: 24565
= 5FF5
d
Signal adaptation via characteristic
Data type: UNSIGNED_16
Index: 24564
= 5FF4
d
h
h
h
717