Window start / end
Via the two parameters Window start (C02813/x) and Window end (C02814/x),
acceptance windows can be set for the DI3 ... DI5 signal sources in which the touch probe
signal is accepted.
 The acceptance windows can be dynamically activated via the inputs at the
LS_TouchProbe
 If the actual position is outside the acceptance window, touch probe is automatically
deactivated.
 If both window limits are set to "0", the acceptance window does not have any effect.
 To properly use this function, the drive needs to know the home position (zero
position).
Position source
Selection of the position signal source to be measured with touch probe. This usually is the
actual position of the motor / encoder position encoder.
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011