Lenze L-force HighLine C 8400 Series Reference Manual page 905

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

C00965
Parameter | Name:
C00965 | Max. motor speed
From version 10.00.00
When the drive reaches the motor speed set here:
• The "Fault" error response takes place, i.e. the motor is shut down immediately.
• The error message
Setting range
(min. value | unit | max. value)
50
Read access
C00966
Parameter | Name:
C00966 | VFC: Time const. slip comp.
Filter time constant of the slip compensation for V/f characteristic control (VFCplus)
• The time constant of slip compensation serves to specify the dynamics of slip compensation for V/f characteristic
control without feedback.
• The lower the selected time constant, the higher the dynamic performance of the slip compensation.
Setting range
(min. value | unit | max. value)
1
Read access
C00967
Parameter | Name:
C00967 | VFC: Frequency interpol. point n
From version 04.00.00
Selection of the interpolation points (frequency values) for the V/f characteristic control (VFCplus) with user-
definable V/f characteristic
Setting range
(min. value | unit | max. value)
-2600.0
Subcodes
C00967/1
C00967/2
C00967/3
C00967/4
C00967/5
C00967/6
C00967/7
C00967/8
C00967/9
C00967/10
C00967/11
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
"OS2: Max. motor speed
rpm
Write access
CINH
PLC STOP
ms
Write access
CINH
PLC STOP
(C00006
= "10")
Hz
Lenze setting
-50.0 Hz
-40.0 Hz
-30.0 Hz
-20.0 Hz
-10.0 Hz
0.0 Hz
10.0 Hz
20.0 Hz
30.0 Hz
40.0 Hz
50.0 Hz
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
reached" is entered into the logbook.
Lenze setting
60000 60000 rpm
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
6000 100 ms
No transfer
COM
MOT
Scaling factor: 1
2600.0
Info
VFC: Frequency interpol. point 1
VFC: Frequency interpol. point 2
VFC: Frequency interpol. point 3
VFC: Frequency interpol. point 4
VFC: Frequency interpol. point 5
VFC: Frequency interpol. point 6
VFC: Frequency interpol. point 7
VFC: Frequency interpol. point 8
VFC: Frequency interpol. point 9
VFC: Frequency interpol. point 10
VFC: Frequency interpol. point 11
No transfer
COM
MOT
Scaling factor: 10
Parameter reference
Parameter list | C00965
Data type: UNSIGNED_16
Index: 23610
= 5C3A
d
h
Data type: UNSIGNED_16
Index: 23609
= 5C39
d
h
Data type: INTEGER_16
Index: 23608
= 5C38
d
h
905