Manual Dc-Injection Braking (Dcb); Automatic Dc-Injection Braking (Auto-Dcb) - Lenze L-force HighLine C 8400 Series Reference Manual

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Motor control (MCTRL)
Parameterisable additional functions
Method
DC-injection braking can be carried out in two ways with different types of activation:

Manual DC-injection braking (DCB)

Automatic DC-injection braking (Auto-DCB)

5.10.5.1
Manual DC-injection braking (DCB)
DC-injection braking can be activated manually for the two technology applications
"Actuating drive speed" and "Switch-off positioning" by connecting the bSetDCBrake input
of the LA_NCtrl or LA_SwitchPos application block to a digital signal source (e.g. via the
digital signal source bCtrl1_B3 of the port block LP_CANIn1).
 For HIGH-active inputs, DC-injection braking is active as long as the signal is at HIGH
level.
 After the hold time (C00107) has expired, the controller sets the pulse inhibit (CINH).
5.10.5.2
Automatic DC-injection braking (Auto-DCB)
"Automatic DC-injection braking" (referred to in the following as "auto DCB") can be used
if there is a requirement that the drive be isolated from the supply at n
Note!
Deactivate automatic DC-injection braking when a holding brake is used!
• For this purpose, go to
• Background: Controller inhibit is already activated by the
control.
254
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
C00019
and set the auto DCB threshold to "0".
( 541)
L
0.
Holding brake
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents