Set/Reset Home Position - Lenze L-force HighLine C 8400 Series Reference Manual

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

3.9.3

Set/reset home position

The measuring system in the machine is selected by means of homing and the zero
position is set within the physical travel range possible.
Detailed information on the "Homing" operating mode is provided in chapter
"Basic drive functions" in subchapter "Homing".
The changeover to the "Homing" operating mode is effected by selecting the option of the
same name on the Positioning tab:
How to set the reference manually with a stopped motor:
Click the Set reference button.
The current actual position in the machine measuring system now corresponds to
the home position set in
Stop!
If you set the reference with the PC manual control, the drive is referenced.
If another home position is required for normal operation:
Click the Cancel reference button and reset the status signals HomPosAvailable
and HomePosDone in the MCK status word in order that no mechanical problems
can occur during normal operation.
• Setpoints and actual positions remain untouched until a renewed reference
setting or homing.
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
8400 HighLine C | Reference manual
( 494)
C01227/2
(Lenze setting: 0.0000 units).