Short overview of the parameters for the frequency inputs:
Parameter
C00011
Frequency input DI1/DI2
C00115/1
C00420/1
C02842/1
C02843/1
C02844/1
C02845
C00443/1
C00445/1
C00446/1
C00449/1
Frequency input DI6/DI7
C00115/2
C00420/2
C02842/2
C02843/2
C00443/1
C00445/2
C00446/2
Highlighted in grey = display parameter
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Info
Appl.: Reference speed
Fct. DI 1/2 200kHz
Encoder increments at FreqIn12
FreqIn12: Offset
FreqIn12: Gain
PosIn12: Function
PosIn12: Comparison value
DIx: Terminal level
FreqIn12_nOut_v
FreqIn12_nOut_a
FreqIn12_dnOut_p
Fct. DI 6/7 10kHz
Encoder increments at FreqIn67
FreqIn67: Offset
FreqIn67: Gain
DIx: Terminal level
FreqIn67_nOut_v
FreqIn67_nOut_a
L
8400 HighLine C | Reference manual
Digital input terminals
0: DI1(6)=In / DI2(7)=In
Loading with level
0: DI1(6)=In / DI2(7)=In
I/O terminals
Lenze setting
Value Unit
1500 rpm
128 Incr./rev.
0.00 %
100.00 %
0
-
- Incr/ms
- %
- Incr
128 Incr./rev.
0.00 %
100.00 %
-
- Incr/ms
- %
317