Lenze L-force HighLine C 8400 Series Reference Manual page 849

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

Parameter | Name:
C00761 | LA_SwitchPos: Digital connection list
C00761/33
C00761/34
C00761/35
C00761/36
C00761/37
C00761/38
C00761/39
C00761/40
C00761/41
C00761/42
C00761/43
C00761/44
C00761/45
C00761/46
C00761/47
Read access
C00762
Parameter | Name:
C00762 | LA_SwitchPos: phi connection list
This code is for device-internal use only and must not be written to by the user!
C00765
Parameter | Name:
C00765 | LA_SwitchPos_Out: Analog signal list
This code is for device-internal use only and must not be written to by the user!
C00766
Parameter | Name:
C00766 | LA_SwitchPos_Out: Digital signal list
This code is for device-internal use only and must not be written to by the user!
C00767
Parameter | Name:
C00767 | LA_SwitchPos_Out: phi signal list
This code is for device-internal use only and must not be written to by the user!
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
LA_SwitchPos: bGPDFlipFlop_InClk
(control input for DFlipFlop clock signal)
LA_SwitchPos: bGPDFlipFlop_InClr
(control input for DFlipFlop reset signal)
Reserved
Reserved
Reserved
Reserved
Reserved
LA_SwitchPos: bFreeIn1
(input for binary user signal 1)
LA_SwitchPos: bFreeIn2
(input for binary user signal 2)
LA_SwitchPos: bFreeIn3
(input for binary user signal 3)
LA_SwitchPos: bFreeIn4
(input for binary user signal 4)
LA_SwitchPos: bFreeIn5
(input for binary user signal 5)
LA_SwitchPos: bFreeIn6
(input for binary user signal 6)
LA_SwitchPos: bFreeIn7
(input for binary user signal 7)
LA_SwitchPos: bFreeIn8
(input for binary user signal 8)
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00762
Data type: UNSIGNED_16
Index: 23814
= 5D06
d
h
Data type: UNSIGNED_16
Index: 23813
= 5D05
d
h
Data type: UNSIGNED_16
Index: 23810
= 5D02
d
h
Data type: UNSIGNED_16
Index: 23809
= 5D01
d
h
Data type: UNSIGNED_16
Index: 23808
= 5D00
d
h
849

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents