Identifier
DIS code | data type
wMaxMotorSpeed
nOutputSpeedCtrl_a
nSpeedCtrlIAct_a
nEffSpeedSetValue_a
nMotorSpeedAct_a
nMotorSpeedAct_v
nMotorFreqAct_a
bLimTorqueSetVal
wMaxMotorTorque
nInputTorqueCtrl_a
nMotorTorqueAct_a
nInputJerkCtrl_a
bLimCurrentSetVal
nStatorCurrentIS_a
nEffCurrentIq_a
nReaktCurrentId_a
nActualFluxx_a
nDCVoltage_a
nMotorVoltage_a
bQspActive
bAutoDCBActive
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Internal interfaces | system block "LS_MotorInterface"
Value/meaning
Reference speed (C00011)
C00011
| BOOL
Speed or slip controller output
• Scaling: 16384 ≡ 100 % reference speed (C00011)
INT
Current value of speed controller integrator
• Scaling depends on the selected motor control:
INT
– V/f control (VFCplus + encoder):
16384 ≡ 100 % reference speed (C00011)
– Servo control (SC) or vector control (SLVC):
16384 ≡ 100 % M
Effective speed setpoint
• Scaling: 16384 ≡ 100 % reference speed (C00011)
INT
Actual speed value
• Scaling: 16384 ≡ 100 % reference speed (C00011)
C00051
| INT
Actual speed value
• Scaling: 65535 ≡ 1 revolution
INT
Current field frequency
C00058
| INT
"Setpoint torque inside the limitation" status signal
BOOL
TRUE The setpoint torque is internally limited
Maximum motor torque
• Scaling: 100 = 0.01 Nm
C00057
From version 06.00.00:
wMaxMotorTorque = 10 * M
Input value of the torque control (torque setpoint)
• Scaling: 16384 ≡ 100 % M
INT
Actual torque
• In the "VFC (+encoder)" motor control mode, this value is determined from the
C00056/2
| INT
current motor current and only approximately corresponds to the actual torque
value..
• Scaling: 16384 ≡ 100 % M
Input value of the jerk limitation
• Scaling: 16384 ≡ 100 % M
INT
"Current setpoint inside the limitation" status signal
BOOL
TRUE The current setpoint is internally limited
Current stator current/effective motor current
• Scaling: 16384 ≡ 100 % I
INT
Current torque-producing cross current
• Scaling: 16384 ≡ 100 % I
INT
Current field-producing direct-axis current
• Scaling: 16384 ≡ 100 % I
INT
Current magnetising current
• Scaling: 16384 ≡ 100 % I
INT
Actual DC-bus voltage
• Scaling: 16384 ≡ 1000 V
INT
Current motor voltage/inverter output voltage
• Scaling: 16384 ≡ 1000 V
INT
"Quick stop active" status signal
BOOL
TRUE Quick stop is active
"Automatic DC-injection braking active" status signal
DC-injection braking ( 253)
BOOL
TRUE Automatic DC-injection braking is active
L
8400 HighLine C | Reference manual
(C00057)
max
(C00057)
max
(C00057)
max
(C00057)
max
(C00057)
max
(C00022)
max_mot
(C00022)
max_mot
(C00022)
max_mot
(C00022)
max_mot
Motor control (MCTRL)