Basic drive functions (MCK)
Basic settings
Note!
An activated limit switch can be retracted again by manual jog in the opposed
direction or with the "Retract limit switch" function.
limit switch
Only in the
bit 10 ("Pos. HW-Limit Detected") or bit 11 ("Neg. HW-Limit Detected") in the
MCK status
Re-activation after acknowledging the error
When the error has been acknowledged and the limit switch is still active, the following
action is required for a renewed activation of the monitoring depending on the operating
mode:
Operating mode
Speed follower
Homing
Manual jog
Positioning
Stop
Position follower
486
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
( 518)
"Manual
jog" operating mode, retracting of the limit switch resets
word.
Action for (re) activation
Limit switch is activated and setpoint in direction of the activated limit switch is pending
Limit switch is activated and bHomStartStop = TRUE
Limit switch is activated and manual jog in direction of the activated limit switch
Limit switch is activated and setpoint command has been transmitted.
Setting of the operating mode
Limit switch is activated and setpoint in direction of the activated limit switch is pending
L
Retracting of an operated