C00272
Parameter | Name:
C00272 | SC: Depth of current setpoint filter
Damping of the current setpoint filter at servo control (SC) and sensorless control for synchronous motors (SLPSM)
Setting range
(min. value | unit | max. value)
0
Read access
C00273
Parameter | Name:
C00273 | Moment of inertia
Moment of inertia for setpoint feedforward control at servo control (SC) and sensorless vector control (SLVC)
Setting range
(min. value | unit | max. value)
0.00
Read access
C00274
Parameter | Name:
C00274 | SC: Max. change in acceleration
Limitation of the acceleration change at servo control (SC) and sensorless control for synchronous motors (SLPSM)
• Setting in % of M_Nenn per ms.
Setting range
(min. value | unit | max. value)
0.0
Read access
C00275
Parameter | Name:
C00275 | Filter setpoint feedforward control
From version 02.00.00
Filter time of setpoint feedforward control at servo control (SC) and sensorless vector control (SLVC)
• The setpoint feedforward control requires the entry of the moment of inertia in C00273.
Setting range
(min. value | unit | max. value)
0.0
Read access
C00276
Parameter | Name:
C00276 | SC: Max. output voltage
From version 02.00.00
Maximum output voltage at servo control (SC)
• Regarding the current DC-bus voltage.
Setting range
(min. value | unit | max. value)
80
Read access
C00280
Parameter | Name:
C00280 | SC: Filter time const. DC detection
Filter time constant for DC-bus voltage filtering
• The filter time constant is e.g. used for field weakening control at servo control (SC).
Setting range
(min. value | unit | max. value)
1
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
dB
Write access
CINH
PLC STOP
kg cm^2
Write access
CINH
PLC STOP
%/ms
Write access
CINH
PLC STOP
ms
Write access
CINH
PLC STOP
%
Write access
CINH
PLC STOP
ms
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Lenze setting
100 0 db
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
600000.00 0.00 kg cm^2
No transfer
COM
MOT
Scaling factor: 100
Lenze setting
400.0 400.0 %/ms
No transfer
COM
MOT
Scaling factor: 10
Lenze setting
1000.0 1.0 ms
No transfer
COM
MOT
Scaling factor: 10
Lenze setting
99 95 %
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
1000 25 ms
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00272
Data type: UNSIGNED_16
Index: 24303
= 5EEF
d
h
Data type: UNSIGNED_32
Index: 24302
= 5EEE
d
h
Data type: UNSIGNED_16
Index: 24301
= 5EED
d
h
Data type: UNSIGNED_16
Index: 24300
= 5EEC
d
h
Data type: UNSIGNED_8
Index: 24299
= 5EEB
d
h
Data type: UNSIGNED_16
Index: 24295
= 5EE7