Optimising the behaviour in the field weakening range

The behaviour in the field weakening range is influenced by:
 the field controller
 the field weakening controller
 the field feedforward control unit
 adaptive adaptation of the P component of the field and speed controllers
 An additional limitation of the I component of the controller when the voltage limit is
reached
Note!
In general, these settings are pre-optimised so that further optimisation is not
required.
Optimisation for special motors (e.g. mid-frequency motors) or for motors
whose power is not adapted can be carried out according to the algorithms
shown in the following sections.