8400 HighLine C | Reference manual
System bus "CAN on board"
Possible settings via DIP switch
10.2.2

Setting the baud rate

The baud rate can be set via code
Note!
• All DIP switches (a ... d, 1 ... 64) = OFF (Lenze setting):
– At switching on, the settings under code
• Preset baud rate: 500 kbps
DIP switch position
d
OFF
OFF
OFF
OFF
OFF
OFF
10.2.3
Setting the node address
The node address can be set via code
 The labelling on the housing corresponds to the values of the individual DIP switches
for determining the node address.
 The valid address range depends on the number of SDO channels set in C00366:
– 1 SDO (Lenze setting): 1 ... 127
– 2 SDO: 1 ... 63
Note!
• The addresses of the nodes must differ from each other.
• All DIP switches (a ... d, 1 ... 64) = OFF (Lenze setting):
– At switching on, the settings under code
Example: Setting of the node address 23
DIP switch
Switch position
Value
Node address
618
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
C00351
C00351
(baud rate) will become active.
c
b
A
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
C00351
(baud rate) will become active.
64
OFF
0
= Sum of the values = 16 + 4 + 2 + 1 = 23
L
or with the DIP switches a to d:
C00350
Baud rate
20 kbps
50 kbps
125 kbps
250 kbps
500 kbps
1000 kbps
C00350
or with the DIP switches 1 to 64.
C00350
32
16
8
OFF
ON
OFF
0
16
0
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
(node address) and
(node address) and
4
2
1
ON
ON
ON
4
2
1

Hide quick links: