Lenze L-force HighLine C 8400 Series Reference Manual page 368

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Technology applications
TA "Actuating drive speed"
Identifier
GP: GeneralPurpose
The following inputs are interconnected with logic/arithmetic functions on application level for free usage.
"GeneralPurpose" functions
nGPAnalogSwitchIn1_a
nGPAnalogSwitchIn2_a
bGPAnalogSwitchSet
nGPArithmetikIn1_a
nGPArithmetikIn2_a
nGPMulDivIn_a
bGPDigitalDelayIn
bGPLogicIn1
bGPLogicIn2
bGPLogicIn3
nGPCompareIn1_a
nGPCompareIn2_a
bGPDFlipFlop_InD
bGPDFlipFlop_InClk
bGPDFlipFlop_InClr
Free inputs
The following inputs can freely be interconnected on the application level.
The signals can be transferred from the I/O level to the application level via these inputs.
bFreeIn1 ... bFreeIn8
wFreeIn1 ... wFreeIn4
Outputs
Identifier
wDriveControlStatus
wStateDetermFailNoLow
wStateDetermFailNoHigh
368
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Information/possible settings
Data type
Analog
switch: Input signals
• The input signal selected via the selection input bGPAnalogSwitchSet is output at
output nGPAnalogSwitchOut_a.
INT
Analog
switch: Selection input
BOOL
FALSE nGPAnalogSwitchOut_a = nGPAnalogSwitchIn1_a
TRUE nGPAnalogSwitchOut_a = nGPAnalogSwitchIn2_a
Arithmetic: Input signals
• The arithmetic function is selected in C00338.
• The result is output at output nGPArithmetikOut_a.
INT
Multiplication/Division: Input signals
• The factor for the multiplication can be set in
INT
C00699/2
(denominator).
• The result is output at output nGPMulDivOut_a.
Binary delay
element: Input signals
• The on-delay can be set in C00720/1.
BOOL
• The off-delay can be set in C00720/2.
• The time-delayed input signal is output at output bGPDigitalDelayOut.
Binary
logic: Input signals
• The logic operation is selected in C00820.
• The result is output at output bGPLogicOut.
BOOL
Analog
comparison: Input signals
• The comparison operation is selected in C00680.
• Hysteresis and window size can be set in
INT
• If the comparison statement is true, the output bGPCompareOut will be set to
TRUE.
D-FlipFlop: Input signals
• Data, clock and reset input
BOOL
Free inputs for digital signals
BOOL
Free inputs for 16-bit signals
WORD
Value/meaning
Data type
Status word of the controller (based on DSP-402)
• The status word contains information on the currents status of the drive
WORD
controller.
• See the
"wDeviceStatusWord status
control for a detailed description of the bit assignment.
Display of the status determining error (LOW word)
WORD
Display of the status determining error (HIGH word)
WORD
L
C00699/1
(numerator) and
C00680
and C00682.
word" subchapter of the chapter on device
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011