C01150
Parameter | Name:
C01150 | L_PhaseIntK: Function
Loading behaviour of the integrator
Selection list
Subcodes
C01150/1
C01150/2
Read access
C01151
Parameter | Name:
C01151 | L_PhaseIntK: Compare
Comparison value
Setting range
(min. value | unit | max. value)
0
Subcodes
C01151/1
C01151/2
Read access
C01201
Parameter | Name:
C01201 | MCK: Cycle
From version 06.00.00
Cycle for Modulo measuring system
• When the cycle is set to 0 units (Lenze setting), the traversing range is unlimited (classical measuring system).
Setting range
(min. value | unit | max. value)
0.0000
Subcodes
C01201/1
Read access
C01202
Parameter | Name:
C01202 | MCK: iM motor/process
Gearbox factor - motor
• Entry of the gearbox factor as numerator/denominator ratio (numerator = motor speed and denominator =
output speed of gearbox) or from the number of teeth of the gearbox arrangement.
Setting range
(min. value | unit | max. value)
1
Subcodes
C01202/1
C01202/2
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 Loading with level
1 Loading with edge
2 Loading with level + reset
Lenze setting
0: Loading with level
0: Loading with level
Write access
CINH
PLC STOP
2147418112
Lenze setting
0
0
Write access
CINH
PLC STOP
units
214748.3647
Lenze setting
0.0000 units
Write access
CINH
PLC STOP
Lenze setting
1
1
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Info
Load integrator with TRUE level at the input bLoad
Load integrator with FALSE/TRUE edge at the input
bLoad
Load integrator when the comparison value (C01151) is
reached or with TRUE level at the bLoad input
Info
L_PhaseIntK_1: Function
L_PhaseIntK_2: Function
No transfer
COM
MOT
Scaling factor: 1
Info
L_PhaseIntK_1: Comparison value
L_PhaseIntK_2: Comparison value
No transfer
COM
MOT
Scaling factor: 1
Activation of the Modulo measuring system
Info
MCK: Cycle
No transfer
COM
MOT
Scaling factor: 10000
65535
Info
MCK: iM: Numerator gearbox factor Z2
MCK: iM: Denominator gearbox factor Z1
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C01150
Data type: UNSIGNED_8
Index: 23425
= 5B81
d
h
Data type: INTEGER_32
Index: 23424
= 5B80
d
h
Data type: INTEGER_32
Index: 23374
= 5B4E
d
h
Data type: UNSIGNED_16
Index: 23373
= 5B4D
d
h
Machine parameter