8400 HighLine C | Reference manual
Device control (DCTRL)
Device state machine and device statuses
4.2.5

ReadyToSwitchOn

LED DRIVE READY
The controller is in this device status directly after the initialisation has been completed!
 The bus systems are running and the terminals and encoders are evaluated.
 The monitoring modes are active.
 The controller can be parameterised.
 The application is basically executable.
Note!
• The "ReadyToSwitchOn" state is not only activated after the mains
connection, but also after the deactivation of "Trouble", "Fault" or
"SafeTorqueOff".
• If
explicit deactivation of the controller inhibit after mains connection is always
required for the controller to change from the "ReadyToSwitchOn" status to
the "SwitchedOn" status.
• If only the 24V voltage supply is available during the mains connection, the
error message
the drive controller and the drive controller remains in the
"ReadyToSwitchOn" status.
Danger!
If the "Inhibit at power-on" auto-start option has been deactivated in C00142,
the "ReadyToSwitchOn status switches directly to the "SwitchedOn" status after
mains connection.
Automatic restart after mains connection/fault...
116
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
LED DRIVE ERROR
OFF
C00142
activates the autostart option "Inhibit at power-on" (Lenze setting),
"LU: Undervoltage in the DC
L
Display in
C00137
Display in status word 1 (C00150)
Bit 11
ReadyToSwitchOn
0
bus" is entered into the logbook of
( 122)
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Bit 10
Bit 9
Bit 8
0
1