C00342
Parameter | Name:
C00342 | CAN decoupling PDOInOut
From version 04.00.00
Configuration defining the events that lead to a decoupling of the process data words.
Setting range
(min. hex value | max. hex value)
0x0000
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Subcodes
C00342/1
C00342/2
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
= bit set)
BusOff_MsgErr
Warning
NodeStopped
HeartBeatEvent
CAN1_In_Überw.
CAN2_In_Überw.
CAN3_In_Überw.
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Trouble
Fault
Lenze setting
0
0
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Configuring exception handling of the CAN PDOs
0xFFFF
Info
CAN decoupling PDO_In from the bus
CAN decoupling PDO_Out from the appl.
No transfer
COM
MOT
Parameter reference
Parameter list | C00342
Data type: UNSIGNED_16
Index: 24233
= 5EA9
d
h
769