8400 HighLine C | Reference manual
Parameter reference
Parameter list | C01081
C01081
Parameter | Name:
C01081 | L_DFRFG_1: Sync. direction / TP function
From version 11.00.00
Selection list
Subcodes
C01081/1
Read access
C01082
Parameter | Name:
C01082 | LS_WriteParamList: Execute Mode
From version 04.00.00
Parameter
change-over: Selection of the activation method
Selection list
(Lenze setting printed in bold)
Read access
C01083
Parameter | Name:
C01083 | LS_WriteParamList: Error status
From version 04.00.00
Parameter
change-over: Error status:
• 0 = no error
• 33803 = Invalid data type (e.g. STRING)
• 33804 = limit violation
• 33806 = invalid code
• 33813 = no element of the selection list
• 33815 = writing of the parameter not permitted
• 33816 = writing of the parameter only permitted if controller is inhibited
• 33829 = invalid subcode
• 33865 = no parameter with subcodes
Display range
(min. value | unit | max. value)
0
Read access
C01084
Parameter | Name:
C01084 | LS_WriteParamList: Error line
From version 04.00.00
Parameter
change-over: Display of the number of list entry where the error occurred (in connection with the value
set selected via bSelectWriteValue_1 and bSelectWriteValue_2).
Display range
(min. value | unit | max. value)
0
Read access
926
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1 cw/ccw - without TP
2 cw - without TP
3 ccw - without TP
4 cw/ccw - with TP
5 cw - with TP
6 ccw - with TP
Lenze setting
1: cw/ccw - without TP
Write access
CINH
PLC STOP
0 by Execute
1 by Input Select
Write access
CINH
PLC STOP
Write access
CINH
PLC STOP
Write access
CINH
PLC STOP
L
Info
L_DFRFG_1: Sync. direction / TP function
No transfer
COM
MOT
Scaling factor: 1
Info
The writing of the parameter list is activated by a
FALSE/TRUE edge at the bExecute input.
The writing of the parameter list is carried out if a change
is made at the select inputs and if the controller is
initialised.
No transfer
COM
MOT
Scaling factor: 1
34000
No transfer
COM
MOT
Scaling factor: 1
32
No transfer
COM
MOT
Scaling factor: 1
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_8
Index: 23494
= 5BC6
d
h
Data type: UNSIGNED_8
Index: 23493
= 5BC5
d
h
Data type: UNSIGNED_16
Index: 23492
= 5BC4
d
h
Data type: UNSIGNED_8
Index: 23491
= 5BC3
d
h