Device Search Function - Lenze L-force HighLine C 8400 Series Reference Manual

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Device control (DCTRL)
Device commands (C00002/x)
4.1.8

Device search function

This function extension is available from version 06.00.00!
In some applications where controllers are installed in control cabinets or are positioned in
a spacious plant, it is often difficult to locate a device connected online for e.g.
maintenance work. There is an established online connection with the device but you do
not know where the controller is located physically.
The
C00002/27
 For the time set in C00181/1, all four status LEDs at the front of the controller flash.
Afterwards, the function is turned off automatically.
 If the device command is executed again within the set time period, the duration is
extended accordingly.
 The setting
 Adjustable time period: 0 ... 6000 s (Lenze setting: 5 s)
Tip!
The device search function can also be activated via the
110
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
= "1: On / start" device command serves to carry out an "optical location":
C00002/27
= "0: Off / ready" serves to abort or switch off the function.
L
toolbar icon.
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011