C00973
Parameter | Name:
C00973 | VFC: Ti V/f +encoder
Integral time constant of the slip regulator for V/f control (VFCplus+encoder)
• In general, the time constant should be selected in a range of 20 ms (high dynamics) to 200 (low dynamics).
Setting range
(min. value | unit | max. value)
0.0
Read access
C00975
Parameter | Name:
C00975 | VFC-ECO: Vp CosPhi controller
From version 10.00.00
Proportional gain of the Cos-Phi controller for energy-saving V/f characteristic control (VFCplusEco)
Setting range
(min. value | unit | max. value)
0.000
Read access
C00976
Parameter | Name:
C00976 | VFC-ECO: Ti CosPhi controller
From version 10.00.00
Reset time of the Cos-Phi controller for energy-saving V/f characteristic control (VFCplusEco)
Setting range
(min. value | unit | max. value)
0.0
Read access
C00977
Parameter | Name:
C00977 | VFC-ECO: Minimum voltage V/f
From version 10.00.00
Minimum voltage V/f of the Cos-Phi controller for energy-saving V/f characteristic control (VFCplusEco)
Setting range
(min. value | unit | max. value)
20.00
Read access
C00978
Parameter | Name:
C00978 | VFC-ECO: Voltage reduction
From version 10.00.00
Display of the voltage reduction with energy-saving V/f characteristic control (VFCplusEco)
Display range
(min. value | unit | max. value)
-1000
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
ms
Write access
CINH
PLC STOP
Hz/Hz
Write access
CINH
PLC STOP
ms
Write access
CINH
PLC STOP
%
Write access
CINH
PLC STOP
V
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Lenze setting
6000.0 100.0 ms
No transfer
COM
MOT
Scaling factor: 10
Lenze setting
64.000 0.500 Hz/Hz
No transfer
COM
MOT
Scaling factor: 1000
Lenze setting
6000.0 200.0 ms
No transfer
COM
MOT
Scaling factor: 10
Lenze setting
100.00 20.00 %
No transfer
COM
MOT
Scaling factor: 100
1000
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00973
Data type: UNSIGNED_16
Index: 23602
= 5C32
d
h
Data type: UNSIGNED_16
Index: 23600
= 5C30
d
h
Data type: UNSIGNED_16
Index: 23599
= 5C2F
d
h
Data type: INTEGER_16
Index: 23598
= 5C2E
d
h
Data type: INTEGER_16
Index: 23597
= 5C2D
d
h
907