dF10: AutoTrip reset [xx.0145.00035]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Too frequent auto-trip reset.
dF50: Retain error [xx.0145.00050]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
An error has occurred when accessing retain data.
• Either caused by an internal hardware error or by lack
of mains switching after a firmware download.
dF51: CuCcr error [xx.0145.00051]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Device error
dF52: BuCcr error [xx.0145.00052]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Device error
Ck01: Pos. HW limit switch [xx.0184.00001]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
MCK: The hardware limit switch in positive traversing
direction has tripped.
• The bLimitSwitchPos input for travel range
monitoring via positive hardware limit switch has
been set to FALSE (fail-safe).
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
L
8400 HighLine C | Reference manual
Diagnostics & error management
Error messages of the operating system
Setting:
C00189
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
• Check the error cause that activates the auto-trip
reset.
• Eliminate error cause and reset (acknowledge) error
manually afterwards.
4: WarningLocked
5: Warning
6: Information
Remedy
Mains switching
• If the problem occurs again, you needs to consult
Lenze.
4: WarningLocked
5: Warning
6: Information
Remedy
Mains switching
• If the problem occurs again, you needs to consult
Lenze.
4: WarningLocked
5: Warning
6: Information
Remedy
Mains switching
• If the problem occurs again, you needs to consult
Lenze.
Setting:
C00595/1
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
Reset error message and retract limit switch.