Basic drive functions (MCK)
Manual jog
8.7.1.1

Functional settings

In C01230, various functional settings for manual jogging can be carried out in bit-coded
form.
Function
Bit 0 Manual jog with intermediate stop
During manual jog, a stop is automatically made at the breakpoint positions set in
C01234/1...4.
• The home position must be known for this function.
• Travelling is continued when the pushbutton is "released" and pressed again. This button
has been assigned the ManJogPos and/or ManJogNeg control function.
Bit 1 Time-based start of second speed
In manual jog mode, an automatic changeover to manual speed 2 takes place after a
parameterisable waiting time.
Time-based start of second speed ( 514)
Bit 2 HW limit switch on
In the "manual jog" operating mode, a travel range monitoring mode via hardware limit
switch is active.
Limit position monitoring ( 483)
Bit 3 SW limit switch on
In the "manual jog" operating mode, a travel range monitoring mode via parameterised
software limit positions.
Limit position monitoring ( 483)
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Position controller off
In the "manual jog" operating mode, the position controller is deactivated. Thus, the
compensation of the following error is switched off.
512
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
L
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Lenze setting
Off
Off
Off
Off
Off
Off
Off
Off