Lenze L-force HighLine C 8400 Series Reference Manual page 812

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Parameter reference
Parameter list | C00595
C00595
Parameter | Name:
C00595 | MCK: Resp. to MCK error
Configuration of monitoring of the Motion Control Kernel
Selection list
Subcodes
C00595/1
C00595/2
C00595/3
C00595/4
C00595/5
C00595/6
C00595/7
C00595/8
C00595/9
C00595/10
C00595/11
C00595/12
C00595/13
C00595/14
C00595/15
Read access
812
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 No Reaction
1 Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Lenze setting
3: TroubleQuickStop
3: TroubleQuickStop
3: TroubleQuickStop
3: TroubleQuickStop
5: Warning
5: Warning
3: TroubleQuickStop
4: WarningLocked
4: WarningLocked
4: WarningLocked
5: Warning
4: WarningLocked
5: Warning
4: WarningLocked
1: Fault
Write access
CINH
PLC STOP
L
Info
Response if the input bLimitSwitchPos for travel range
monitoring is set to FALSE (fail-safe) by the positive
hardware limit switch .
Response if the input bLimitSwitchNeg for travel range
monitoring is set to FALSE (fail-safe) by the negative
hardware limit switch .
Response for detection that the position is beyond the
positive software limit position (C01229/1).
Response for detection that the position is beyond the
negative software limit position (C01229/2).
Response if following error limit 1 is exceeded
(C01215/1)
Response if following error limit 2 is exceeded
(C01215/2)
Response if the maximum travel distance (display in
C01213/1) is exceeded
Response to start procedures with reference condition
when the reference is not set
Response to a non-supported positioning mode
Response to implausible profile set data
Response to the selection of an invalid operating mode
of the MCK
Response to indicating an invalid profile data set
Response to an error of the FB
Response to a profile start with a target position outside
the software limit positions
Response to activated connection monitoring in case of
PC manual control
From version 06.00.00
No transfer
COM
MOT
Scaling factor: 1
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_8
Index: 23980
= 5DAC
d
h
Basic drive functions
L_MckCtrlInterface_1
(C01229/1
and C01229/2).