Ramp Time For Approaching The Setpoint Speed - Lenze L-force HighLine C 8400 Series Reference Manual

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8.12.2.5

Ramp time for approaching the setpoint speed

For the
"Speed
setpoint is already out of reach while the holding brake is initiating the feedforward
control process.
Note!
The "Homing",
different control/release process of the holding brake. In these operating modes,
the
C02610/1
Example:
A setpoint of 90 % is selected via the ramp function generator while the brake is applied
(controller is inhibited).
1. At the set ramp (in most cases C00012), the ramp function generator ramps up to 90 %.
2. The brake identifies the setpoint selection of 5 % (release switching threshold). The
feedforward control of the brake provides 3 % of the setpoint and will not report the
release of the brake after approx. 1 s has expired.
Conclusion: 90 % of the selected setpoint is already ramped up while the brake is only
providing 3 % of the setpoint via the feedforward control.
Since at this point a step change from 3 % to 90 % may cause mechanical jerks, the setpoint
is ramped up from 3 % to 90 %, using the ramp time set in
Our example is based on the V/f characteristic control (VFCplus) operating mode since the
servo control (SC) operating mode does not use the switching threshold for the application
of the holding brake for speed feedforward control. However, ramping up to a setpoint
that is out of reach is carried out for all motor control operating modes because there is
always a mechanical/electric delay when controlling a holding brake.
This delay is due to:
 Motor magnetisation (in the case of servo control only)
 Mechanical delay of all switching elements connected upstream to the holding brake
 Mechanical delay of the holding brake itself
 Generation of the holding torque by the motor
Related topics:
Process when brake is released
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
follower" operating mode, a ramp time can be set in
"Manual
jog", and "Positioning" operating modes are based on a
setting parameter does not have any effect!
( 553)
L
8400 HighLine C | Reference manual
Basic drive functions (MCK)
C02610/1
Holding brake control
C02610/1
if the
(Lenze setting: 2 s).
551

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents