8400 HighLine C | Reference manual
Device control (DCTRL)
Device commands (C00002/x)
4.1.1

Load Lenze setting

The
C00002/1
which are saved in the controller firmware.
 Can only be executed if the controller is inhibited; otherwise, the feedback
= "6: No access - controller inhibit" will be returned.
 All parameter changes which have been carried out after the last time the parameter
set was saved will be lost!
 This device command has an effect on the settings of the parameters of the operating
system, application and module.
How to load the Lenze setting:
1. If the controller is enabled, it must be inhibited, e.g. by executing the
"Enable/Inhibit controller" device command
2. Execute the "Load Lenze setting" device command:
C00002/1
The loading process may take a couple of seconds. After the device command has
been called,
20%"  "Work in progress 40 %"  "Work in progress 60 %", etc.).
104
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
= "1: On / start" device command resets the parameters to the Lenze setting
= "1: On / start"
C00002/1
returns dynamic status information ("Work in progress
L
(C00002/16
= "0: Off / ready").
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
C00002/1