Lenze L-force HighLine C 8400 Series Reference Manual page 943

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

C01224
Parameter | Name:
C01224 | MCK: Ref. speeds
Speeds for reference search/homing
Setting range
(min. value | unit | max. value)
0.0000
Subcodes
C01224/1
C01224/2
Read access
C01225
Parameter | Name:
C01225 | MCK: Ref. accelerations
Accelerations for reference search/homing
Setting range
(min. value | unit | max. value)
0.0000
Subcodes
C01225/1
C01225/2
Read access
C01226
Parameter | Name:
C01226 | MCK: Ref. S-ramp time
S-ramp time for reference search/homing
• Setting "0 s" ≡ no rounding
Setting range
(min. value | unit | max. value)
0.000
Subcodes
C01226/1
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
unit/s
214748.3647
Lenze setting
720.0000 unit/s
180.0000 unit/s
Write access
CINH
PLC STOP
unit/s2
214748.3647
Lenze setting
720.0000 unit/s2
720.0000 unit/s2
Write access
CINH
PLC STOP
s
Lenze setting
0.000 s
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Info
MCK: Ref. initial speed
• Starting speed for approaching the pre-stop signals.
MCK: Ref. search speed
• Search speed for detecting the reference initiator.
No transfer
COM
MOT
Scaling factor: 10000
Info
MCK: Ref. initial acceleration
• Starting acceleration for the starting speed ramps.
MCK: Ref. search acceleration
• Search acceleration for the search speed ramps.
No transfer
COM
MOT
Scaling factor: 10000
10.000
Info
MCK: Ref. S-ramp time
• S-ramp time for the starting and search speed ramps.
No transfer
COM
MOT
Scaling factor: 1000
Parameter reference
Parameter list | C01224
Data type: INTEGER_32
Index: 23351
= 5B37
d
h
Homing
Data type: INTEGER_32
Index: 23350
= 5B36
d
h
Homing
Data type: UNSIGNED_16
Index: 23349
= 5B35
d
h
Homing
943

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents