14.2
Parameter list
This chapter lists all parameters of the operating system in numerically ascending order.
Note!
The parameter descriptions are based on the software version V11.00.00.
C00002
Parameter | Name:
C00002 | Device command
Note:
• Before switching off the supply voltage after carrying out a device command, check whether the device
command has been carried out successfully via the status display under C00003!
• Before activating device commands by a master control, wait for the "Ready" signal of the controller.
• The device will reject a write process to C00002/x if the value is >1 and issue an error message.
Selection list
Subcodes
C00002/1
C00002/2
C00002/3
C00002/4
C00002/5
C00002/6
C00002/7
C00002/8
C00002/9
C00002/10
C00002/11
C00002/12
C00002/13
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 Off / ready
1 On / start
4 Action cancelled
5 No access
6 No access controller inhibit
20 20% working
40 40% working
60 60% working
80 80% working
Lenze setting
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
L
8400 HighLine C | Reference manual
Drive control
Info
Load Lenze setting
• All parameters are reset to the Lenze setting.
• Only possible when the controller is inhibited.
Reserved
Reserved
Reserved
Reserved
Load all parameter sets
• All parameter sets are loaded by the memory module.
• Only possible when the controller is inhibited.
Reserved
Reserved
Reserved
Reserved
Save all parameter sets
• All parameter sets are saved to the memory module
safe against mains failure.
Reserved
Reserved
Parameter reference
Parameter list
Data type: UNSIGNED_8
Index: 24573
= 5FFD
d
h
(DCTRL):
Device commands
709