7
Commissioning
)
Note!
Please observe:
ƒ
ƒ
7.1
Before switching on
)
Note!
ƒ
ƒ
To prevent injury to persons or damage to material assets, check ...
... before connecting the mains voltage:
Wiring for completeness, short circuit, and earth fault
ƒ
The "EMERGENCY STOP" function of the entire system
ƒ
The motor circuit configuration (star/delta) must be adapted to the output voltage
ƒ
of the controller
The in−phase connection of the motor
ƒ
The direction of rotation or the incremental encoder (if available)
ƒ
... the most important drive parameter settings before the controller is enabled:
Is the V/f rated frequency adapted to the motor circuit configuration?
ƒ
Are the drive parameters relevant for your application set correctly?
ƒ
Is the configuration of the analog and digital inputs and outputs adapted to wiring?
ƒ
EDS84ASC552 EN 6.0
efesotomasyon.com - Lenze
the general safety instructions (¶ 11)
the residual hazards (¶ 17).
Comply with the corresponding switch−on sequence.
In case of faults during commissioning please use:
– the chapter "Diagnostics"
– the online help in the »Engineer«
– the 8400 StateLine C or 8400 HighLine C software manual
l
Commissioning
Before switching on
7