C00079
Parameter | Name:
C00079 | SC: Settings
Configuration of different options for servo control (SC) and sensorless control for synchronous motors (SLPSM)
Selection list
Subcodes
C00079/1
C00079/2
C00079/3
C00079/4
Read access
C00080
Parameter | Name:
C00080 | Override point of field weakening
Offset of the override point of field weakening
• In the V/f characteristic control mode (VFCplus), the stall protection function or the max. permissible current in
the field weakening range can be adapted.
Setting range
(min. value | unit | max. value)
-500
Read access
C00081
Parameter | Name:
C00081 | Rated motor power
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Note:
It is mandatory to give the rated motor power for the sensorless vector control (SLVC) and the servo control (SC).
Setting range
(min. value | unit | max. value)
0.00
Read access
C00082
Parameter | Name:
C00082 | Motor rotor resistance
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range
(min. value | unit | max. value)
0
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 Off
1 On
Lenze setting
0: Off
1: On
0: Off
1: On
Write access
CINH
PLC STOP
Hz
Write access
CINH
PLC STOP
kW
Write access
CINH
PLC STOP
mOhm
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Info
SC: Current controller - feedforward control
• Feedforward control/decoupling network of the
current controller.
SC: Adapt. field weakening controller
• Speed-dependent adaptive field weakening
controller.
SC: n-ctrl anti-wind-up
• "Anti-wind-up" effect of the speed controller in case
of an output voltage limitation in the field weakening
range.
Field weakening for synchronous motors
From version 11.00.00
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
500 0 Hz
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
500.00 11.00 kW
No transfer
COM
MOT
Scaling factor: 100
Lenze setting
200000 276 mOhm
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00079
Data type: UNSIGNED_8
Index: 24496
= 5FB0
d
h
Data type: INTEGER_16
Index: 24495
= 5FAF
d
h
Data type: UNSIGNED_16
Index: 24494
= 5FAE
d
h
Data type: UNSIGNED_32
Index: 24493
= 5FAD
d
h
729