Lenze L-force HighLine C 8400 Series Reference Manual page 751

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

C00169
Parameter | Name:
C00169 | Logbook setting
Configuration which message types are to be logged in the logbook.
Setting range
(min. hex value | max. hex value)
0x0000
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Read access
C00170
Parameter | Name:
C00170 | Current error
Display of the internal error number of the currently pending error
Display range
(min. value | unit | max. value)
0
Read access
C00171
Parameter | Name:
C00171 | Logbook access index
This code is for device-internal use only and must not be written to by the user!
C00173
Parameter | Name:
C00173 | Mains voltage
If the rated mains voltage differs from 230 V or 400 V, set the mains voltage the drive is operated with.
The set mains voltage influences the brake chopper threshold, the monitoring of the device utilisation (Ixt) and the
switch-off threshold in case of undervoltage in the DC bus.
Selection list
(Lenze setting printed in bold)
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
= bit set)
Reserved
Log entry: Fault
Log entry: Trouble
Log entry: TroubleQuickstop
Log entry: WarningLocked
Log entry: Warning
Log entry: Information
Reserved
Reserved
Activation: Error counter
Activation: Log line refresh
Reserved
Reserved
Reserved
Reserved
Reserved
Write access
CINH
PLC STOP
4294967295
Write access
CINH
PLC STOP
0 3ph 400V / 1ph 230V
1 3ph 440V / 1ph 230V
2 3ph 480V / 1ph 230V
3 3ph 500V / 1ph 230V
4 3ph 400V / 1ph 115V
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Lenze setting
0xFFFF 0x067E (decimal: 1662)
No transfer
COM
MOT
No transfer
COM
MOT
Scaling factor: 1
Info
3-phase 400 V or 1-phase 230 V
3-phase 440 V or 1-phase 230 V
3-phase 480 V or 1-phase 230 V
3-phase 500 V or 1-phase 230 V
3-phase 400 V or 1-phase 115 V
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00169
Data type: UNSIGNED_16
Index: 24406
= 5F56
d
h
Data type: UNSIGNED_32
Index: 24405
= 5F55
d
h
Data type: UNSIGNED_8
Index: 24404
= 5F54
d
h
Data type: UNSIGNED_8
Index: 24402
= 5F52
d
h
751