Lenze L-force HighLine C 8400 Series Reference Manual page 597

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

Sd3: Open circuit - feedback system [xx.0123.00205]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
• HTL encoder cable interrupted.
• HTL encoder is defective.
Note: May also be caused by a very dynamic acceleration
or starting up against a blocked motor shaft (e.g. with a
closed holding brake).
An01: AIN1_I < 4 mA [xx.0125.00001]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Open-circuit monitoring for analog input 1 has tripped.
• Only if the analog input has been configured as a
current loop of 4 ... 20
An02: AIN2_I < 4 mA [xx.0125.00002]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Open-circuit monitoring for analog input 2 has tripped.
• Only if the analog input has been configured as a
current loop of 4 ... 20
CE04: MCI communication error [xx.0127.00002]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Communication error with extension module in slot 1.
CE0F: MCI control word [xx.0127.00015]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Bit 14 ("SetFail") of the wMciCtrl control word of the
LS_DriveInterface
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
(C00034/1
= 2).
1: Fault
2: Trouble
3: TroubleQuickStop
(C00034/2
= 2).
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
system block has been set.
L
8400 HighLine C | Reference manual
Diagnostics & error management
Error messages of the operating system
Setting:
C00586
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
• Check HTL encoder cable.
• Check HTL encoder.
• Check related terminals.
• Switch off monitoring
(C00603/
the HTL encoder is not used.
Setting:
C00598/1
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
• Check wiring of the analog X3/A1I input terminal for
open circuit.
• Check minimum current values of the signal sources.
Setting:
C00598/2
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
• Check wiring of the analog X3/A2I input terminal for
open circuit.
• Check minimum current values of the signal sources.
Setting:
C01501/1
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
• Eliminate EMC interference.
• Switch off controller, correctly plug in the module,
switch on the controller again.
• Mains switching or restart of the controller,
respectively.
• Replace module/controller.
• If the problem occurs again, you needs to consult
Lenze.
Setting:
C00594/2
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
Trace back signal source on the bus (e.g. PROFIBUS) that
sets bit 14 ("SetFail").
= "0: No reaction") is
597

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents