5.3

Defining current and speed limits

Limitation of the speed setpoint
Parameterising the reference speed in
speed if a speed setpoint of 100% is specified.
All speed setpoint selections are provided in % and always refer to the reference speed set
in C00011.
Tip!
For reasons of achievable resolution and the accuracy involved, the reference
speed should be geared to the speed range required for the respective application.
Lenze recommendation: Reference speed (C00011) = 1500 ... 3000 rpm
Irrespective of the selected motor control, there are more limitation options:
Parameter
C00909/1
C00909/2
C00910/1
C00910/2
Note!
In the torque-controlled operation (bTorquemodeOn = TRUE), the limitation of
the speed setpoint does not have any effect! In this case, a permissible speed
range can be defined via speed limitation (nSpeedHighLimit and
nSpeedLowLimit).
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
C00011
Info
Max. positive speed
Max. negative speed
Max. positive output frequency
Max. negative output frequency
L
8400 HighLine C | Reference manual
Motor control (MCTRL)
Defining current and speed limits
means that the drive must rotate at the set
Lenze setting
Value Unit
120 %
120 %
1000 Hz
1000 Hz