8400 HighLine C | Reference manual
Parameter reference
Parameter list | C00159
C00159
Parameter | Name:
C00159 | Cause of quick stop QSP
Bit coded display of the cause/source of the quick stop
Display area
(min. hex value | max. hex value)
0x0000
Value is bit-coded:
Bit 0 Reserved
Bit 1 CAN control word
Bit 2 MCI control word
Bit 3 Reserved
Bit 4 Application
Bit 5 Device command
Bit 6 Error response
Bit 7 Internal signal
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Operating system
Bit 11 Reserved
Bit 12 MCK
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access
C00160
Parameter | Name:
C00160 | Status determining error (16bit)
From version 06.00.00
Display of the status determining error as short 16-bit error number
Display range
(min. value | unit | max. value)
0
Subcodes
C00160/1
Read access
744
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Write access
CINH
PLC STOP
Write access
CINH
PLC STOP
L
0xFFFF
No transfer
COM
MOT
65535
Info
Status determining error (16-bit)
No transfer
COM
MOT
Scaling factor: 1
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_16
Index: 24416
= 5F60
d
h
Data type: UNSIGNED_16
Index: 24415
= 5F5F
d
h