8400 HighLine C | Reference manual
Basic drive functions (MCK)
Homing
Mode 13: <_Ln
 Negative travel range limit switch
Mode 13
Lp
Ln
Functional sequence:
1. Movement in negative direction with start profile data set.
2. Positive edge of the travel range limit switch sets reference.
Note!
The load machine can also leave the travel range limit switch. There follows a
return to the home position that was set with the positive edge of the travel
range limit switch.
• It is possible that, as a result, the machine will remain on an operated limit
switch.
• It is therefore recommended that a home value offset be set in
order to release the operated limit switch.
504
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1
0
<
Start speed
Inactive
Inactive
L
Ln
Offset path
Inactive
Active
Inactive
Inactive
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Sequence profile (optional)
Profile speed
Active
Active
C01227/1