Diagnostics & error management
Error messages of the operating system
9.9.5

Short overview (A-Z)

The table below contains all error messages of the controller operating system in
alphabetical order.
Note!
For the sake of legibility, the
number with the following syntax:
[Error type].[Error subject area no.].[Error ID]
In this documentation, "xx", a wildcard, stands for the error type since it is
configurable for many error messages.
Tip!
If you click the cross-reference in the first column, "Error number", you will reach
the detailed description of the respective error message in the following chapter,
"Cause & possible
Error number
32 bits
16 bits
16 bits
hex
xx.0125.00001
0x1901
xx.0125.00002
0x1902
xx.0131.00006
0x1f06
xx.0131.00007
0x1f07
xx.0131.00008
0x1f08
xx.0131.00011
0x1f0b
xx.0131.00015
0x1f0f
xx.0127.00002
0x1b02
xx.0127.00015
0x1b0f
xx.0135.00001
0x2301
xx.0135.00002
0x2302
xx.0135.00003
0x2303
xx.0131.00000
0x1f00
xx.0184.00001
0x5401
21505
xx.0184.00002
0x5402
21506
xx.0184.00007
0x5407
21511
xx.0184.00008
0x5408
21512
xx.0184.00153
0x5499
21657
xx.0184.00154
0x549a
21658
xx.0184.00155
0x549b
21659
xx.0184.00156
0x549c
21660
xx.0184.08005
0x54cd
21709
xx.0184.08007
0x54cf
21711
xx.0184.08009
0x54d1
21713
xx.0184.08014
0x54d6
21718
xx.0184.08015
0x54d7
21719
xx.0184.00015
0x540f
21519
xx.0184.00005
0x5405
21509
xx.0184.00064
0x5440
21568
586
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
remedies".
Error message
dec
6401
An01: AIN1_I < 4 mA
6402
An02: AIN2_I < 4 mA
7942
CA06: CAN CRC error
7943
CA07: CAN bus warn
7944
CA08: CAN Bus Stopped
7947
CA0b: CAN HeartBeatEvent
7951
CA0F: CAN control word
6914
CE04: MCI communication error
6927
CE0F: MCI control word
8961
CE1: CAN RPDO1
8962
CE2: CAN RPDO2
8963
CE3: CAN RPDO3
7936
CE4: CAN Bus Off
Ck01: Pos. HW limit switch
Ck02: Neg. HW limit switch
Ck03: Pos. SW limit position
Ck04: Neg. SW limit position
Ck05: Error following error 1
Ck06: Following Error 2
Ck07: Travel range limit exceeded
Ck08: Home position unknown
Ck09: Positioning mode invalid
Ck10: Profile data implausible
Ck11: Operating mode invalid
Ck12: Profile no. invalid
Ck13: Error FB MCKCtrlInterface
Ck14: Target position beyond SW limit position
Ck15: Error status sign. brake
Ck16: Time overflow manual control
L
Logbook
and
C00165
display the 32-bit error
( 589)
Response
(Lenze setting)
TroubleQuickStop
TroubleQuickStop
No Reaction
No Reaction
No Reaction
No Reaction
Fault
No Reaction
Fault
No Reaction
No Reaction
No Reaction
No Reaction
TroubleQuickStop
TroubleQuickStop
TroubleQuickStop
TroubleQuickStop
Warning
Warning
TroubleQuickStop
WarningLocked
WarningLocked
WarningLocked
Warning
WarningLocked
Warning
WarningLocked
Fault
Fault
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
can be set in
CAN Emergency
Error Code
C00598/1
0xF000
C00598/2
0xF000
C00592/1
0x8000
C00592/3
0x8000
C00592/4
0x8000
C00592/5
0x8130
C00594/2
0xF000
C01501/1
0x7000
C00594/2
0xF000
C00593/1
0x8100
C00593/2
0x8100
C00593/3
0x8100
C00592/2
0x8000
C00595/1
0x8600
C00595/2
0x8600
C00595/3
0x8600
C00595/4
0x8600
C00595/5
0x8611
C00595/6
0x8611
C00595/7
0x8612
C00595/8
0x8612
C00595/9
0x8600
C00595/10
0x8600
C00595/11
0x8600
C00595/12
0x8600
C00595/13
0x8600
C00595/14
0x8600
-
0x8600
-