Drive Diagnostics Via Keypad/Bus System - Lenze L-force HighLine C 8400 Series Reference Manual

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

9.4

Drive diagnostics via keypad/bus system

Keypad display of the controller status
Symbol
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
 When the keypad is connected to the diagnostic
interface X6 at the front of the controller, the status of
the controller is displayed via different symbols on the
LCD display in the area
Meaning
Controller is switched on.
Controller is enabled.
Application in the controller is stopped.
Quick stop is active
Controller is inhibited.
Controller is ready to switch on.
Speed controller 1 in the limitation.
Set current limit has been exceeded in motor
or generator mode.
Pulse inhibit is active
System fault is active
Fault
Trouble
TroubleQSP
Warning is active
L
8400 HighLine C | Reference manual
Diagnostics & error management
Drive diagnostics via keypad/bus system
.
Note
SwitchedOn ( 117)
The power outputs are inhibited.
ReadyToSwitchOn ( 116)
The drive is torque-controlled.
The power outputs are inhibited.
Fault ( 121)
Trouble ( 120)
TroubleQSP ( 119)
565

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents